Introduction

The process to set the Z origin manually with a sheet of paper is described in the guide 03 - Set The User Origin. This guide describes how to use the tool sensor to automatically probe and set the Z origin using a custom macro program.

  1. Where you place the sensor depends on how your CAM program is set up. Ususally this will be the machine spoilboard surface or the top surface of your material. Find a clear flat spot to place the sensor. Try to avoid areas that have been machined or damaged.
    • Where you place the sensor depends on how your CAM program is set up. Ususally this will be the machine spoilboard surface or the top surface of your material.

    • Find a clear flat spot to place the sensor.

    • Try to avoid areas that have been machined or damaged.

    • Place the sensor flat on the surface. Make sure it sits level and does not rock back and forth.

    • Use the steel plate to hold it in place so it does not shift during probing.