  1. Loosen the table locking collar by turning the red handle on the side of the column counter-clockwise.
    • Loosen the table locking collar by turning the red handle on the side of the column counter-clockwise.

    • Failure to unlock the table prior to attempting to adjust it will damage the column rack.

  2. Locate the adjusting crank on the right side of the column.
    • Locate the adjusting crank on the right side of the column.

    • Turn the crank clockwise to lower the table.

    • Turn the crank counter-clockwise to raise the table.

  3. Turn the red-handled column lock clockwise to lock the table in position.
    • Turn the red-handled column lock clockwise to lock the table in position.

    • Failure to lock the table prior to drilling will put the force of drilling on the fragile gear rack that raises and lowers the table rather than the column itself.