Skip to main content
  1. Loosen the table locking collar by turning the red handle on the side of the column counter-clockwise.
    • Loosen the table locking collar by turning the red handle on the side of the column counter-clockwise.

    • Failure to unlock the table prior to attempting to adjust it will damage the column rack.

  2. Locate the adjusting crank on the right side of the column.
    • Locate the adjusting crank on the right side of the column.

    • Turn the crank clockwise to lower the table.

    • Turn the crank counter-clockwise to raise the table.

  3. Turn the red-handled column lock clockwise to lock the table in position.
    • Turn the red-handled column lock clockwise to lock the table in position.

    • Failure to lock the table prior to drilling will put the force of drilling on the fragile gear rack that raises and lowers the table rather than the column itself.

Finish Line

Brian Adams

Member since: 02/26/2018

8,892 Reputation

54 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 1

All Time: 35